Calibration management software
No overdue gauges, no missing certificates, no scramble before the audit.
MaintenanceIQ is calibration management software that turns each instrument's schedule into due calibrations, keeps the uploaded PDF certificate as proof on every one and records the lab or vendor behind it. It helps your quality head walk into an audit with the calibration log ready and your maintenance planner keep instruments in date.
The problem
One overdue gauge puts every reading since in question
Your quality head knows the pattern. The auditor picks a pressure gauge on a critical line, asks for its calibration certificate, and the certificate is either in a vendor's email, in a file on the wrong shared drive, or a month out of date.
An overdue calibration is one of the quickest findings an auditor can raise, because it is easy to check and hard to argue with. Worse, it raises a real question: were the measurements taken with that instrument since its last good check actually right?
Instrument calibration is rarely hard work. Keeping track of hundreds of due dates, labs and certificates across a plant is where it slips.
What calibration management software should keep for you
You set a calibration schedule once per instrument, with a recurrence of monthly, quarterly, half-yearly or yearly. MaintenanceIQ generates each calibration instance with its due date, so due and overdue calibrations sit beside the rest of your maintenance instead of in a separate file.
When the calibration is done, your team uploads the lab's PDF certificate to that instance as proof, with the lab or vendor and whether it is NABL accredited. The record and its evidence stay together.
- Instrument schedules that generate calibration instances
- Recurrence: monthly, quarterly, half-yearly or yearly
- An uploaded PDF certificate kept as proof on every instance
- Vendor and NABL tracking for traceability
Built around how instruments really sit in a plant
A gauge is usually fitted to a machine. The schedule should know that.
Schedule for the machine or the instrument on it
Calibrate the asset as a whole, or the specific pressure gauge, thermocouple or load cell installed on it.
How: Schedules for an asset or a specific installed instrument-part. The part is optional, with a warning if you leave it out.
Upcoming and history on the asset
Your technician opens the machine and sees what is due and what was done, for the machine and every instrument on it.
How: The asset's Calibration tab lists upcoming and past schedules at asset and part level, each linked.
Learn moreCertificates that are easy to find
No more hunting through email for last year's certificate.
How: Each calibration certificate is uploaded as a PDF and kept as proof on its calibration instance.
Retire or remove with control
Retire a schedule when an instrument leaves service, and only the right people can delete one.
How: Retire a schedule, or delete it with the calibration delete permission.
A calibration log for the auditor
Give the auditor one document instead of a folder of files.
How: The Calibration Log section of the compliance evidence pack, with who, when and status on every row.
Learn moreReports on a schedule
Your quality head gets the calibration due list without asking for it.
How: A Calibration dataset in the report builder, exportable to CSV and schedulable daily, weekly or monthly in the morning digest.
NABL calibration and traceability, in plain terms
Traceability means a reading on your shop-floor instrument can be followed, through a chain of calibrations, back to a national or international standard. In India, labs accredited by NABL (the National Accreditation Board for Testing and Calibration Laboratories) are commonly used to show that chain. Elsewhere, your auditor will look for an equivalent accredited lab.
MaintenanceIQ records which vendor did each calibration and whether it was NABL, and keeps the uploaded certificate on the record as proof. Checking the certificate itself, its reference standards and stated uncertainty, stays with your quality team. Our guide on calibration traceability explains what auditors check first.
A quarterly gauge that comes back out of tolerance
Worked example (illustrative)
The CAL-04 pressure gauge (illustrative instrument) is installed on the HP-11 press (illustrative machine) and calibrated quarterly. It was last calibrated on 10 January, so the next calibration is generated for 10 April.
On 10 April the lab reports CAL-04 is reading outside its tolerance. Your team uploads the lab's certificate to the instance, raises a corrective work order on HP-11 to replace the gauge, and starts an impact review of everything measured with it since 10 January.
| Item | Value |
|---|---|
| Last good calibration | 10 January |
| Recurrence | Quarterly, so 3 months |
| Next due | 10 April |
| Window under review | 10 January to 10 April, about 90 days of readings |
| Records kept | Uploaded certificate on the instance, corrective work order on the asset, both with who and when |
The calibration log shows the due date was met, the result and the fix. The impact review itself follows your quality procedure; MaintenanceIQ keeps the records it relies on together.
Frequently asked questions
Does MaintenanceIQ store calibration certificates?
Yes. Your team uploads the PDF certificate from the lab or vendor to each calibration instance, where it is kept as proof, with the vendor and NABL details recorded alongside it. MaintenanceIQ does not generate certificates.
What recurrence options are there?
Monthly, quarterly, half-yearly and yearly. Each schedule generates calibration instances with due dates that show up with the rest of your maintenance.
Can I calibrate an instrument that is fitted to a machine?
Yes. You can schedule calibration for the asset or for a specific installed instrument-part, and the asset's Calibration tab shows upcoming and past calibrations for both.
Is MaintenanceIQ a NABL accredited lab?
No. MaintenanceIQ records which lab or vendor calibrated each instrument and whether it was NABL, and keeps the uploaded certificate as proof. Accreditation belongs to the lab.
Keep reading
Compliance and audit
Evidence packs with a calibration log, frozen as immutable records.
ReadAsset management software
The machine record your instruments are installed on.
ReadCalibration traceability
The evidence auditors check first, and how to keep it unbroken.
ReadNABL calibration records
What to keep from a NABL certificate, and what the software does not do.