GHG emissions calculation for factories: Scope 1, 2 and 3 basics
A GHG emissions calculation multiplies what you used, such as litres of diesel or units of electricity, by an emission factor for that fuel or grid, and adds the results up in tonnes of CO2 equivalent (tCO2e). Scope 1 is what you burn or release inside your own fence, Scope 2 is the electricity, steam or heat you buy, and Scope 3 is everything else in your value chain. Most factories start with Scope 1 and 2, because the data already sits in fuel logs, refrigerant records and power bills.
What Scope 1, 2 and 3 mean in a factory
The three scopes come from the GHG Protocol Corporate Standard, the framework most reporting schemes build on. They exist so that two companies do not count the same tonne twice, and so that you know which emissions you control directly. In India, the Business Responsibility and Sustainability Report that SEBI requires from the largest listed companies asks for Scope 1 and 2 figures, so their suppliers are often asked for the same numbers.
Scope 1: direct emissions. These come from sources you own or control. In a factory that means fuel burnt in furnaces, boilers, ovens and DG sets; diesel in your own forklifts and vehicles; process emissions from chemical reactions; and gases that leak, such as refrigerant from chillers and air conditioners or SF6 from high voltage switchgear.
Scope 2: indirect emissions from energy you buy. Mostly grid electricity, plus any steam, heat or cooling bought from outside. The emissions happen at the power station, but your demand causes them.
Scope 3: all other indirect emissions. The GHG Protocol splits these into 15 categories. For a plant the big ones are usually purchased materials such as steel, alloys and resins, inbound and outbound transport, waste, business travel and, for some products, the energy they use in the customer's hands.
The GHG emissions calculation in one line
Emissions (tCO2e) = Activity data x Emission factor x GWP- Activity data
- How much you used: litres of diesel, kg of LPG, kWh of electricity, kg of refrigerant topped up.
- Emission factor
- How much gas each unit releases, for example kg CO2 per litre of diesel or tonnes CO2 per MWh of grid power. Use a published source and write down which one.
- GWP
- Global warming potential. It converts methane, nitrous oxide, refrigerants and SF6 into CO2 equivalent. For CO2 itself the GWP is 1.
GWP values change between IPCC assessment reports. Pick one report, say which, and use it for every gas and every year you compare.
For fuels, the IPCC 2006 Guidelines give default factors per unit of energy, which you convert to litres or kilograms using the fuel's heating value. For grid electricity in India, the Central Electricity Authority publishes a CO2 baseline database with a grid emission factor that is updated from time to time. Always use the latest version and note the version number next to your result.
Scope 2 has one extra rule. The GHG Protocol Scope 2 Guidance asks for two figures: a location-based figure using the average grid factor, and a market-based figure that reflects any renewable power you contract, for example through open access or renewable energy certificates. If you buy no renewable power, the two are often the same.
A source register to copy
Start with one row per emission source, not one row per gas. Fill in where the number comes from before you worry about the factor. If nobody owns the data, the row will be empty next year.
| Source | Scope | Activity data and unit | Where the data comes from | Factor and its source | Owner |
|---|---|---|---|---|---|
| Furnace and boiler fuel (LPG, PNG, furnace oil, coal) | 1 | kg, SCM or litres per month | Purchase invoices, stock register, flow meter | IPCC default or supplier value | Utilities |
| DG sets | 1 | Litres of diesel per month | DG fuel log, run hour meter | IPCC default | Maintenance |
| Own vehicles and forklifts | 1 | Litres of diesel or kg of LPG | Fuel issue register | IPCC default | Stores |
| Refrigerant top-ups (chillers, AC, cold rooms) | 1 | kg added, by gas type | Work orders and service reports | GWP from one IPCC report | Maintenance |
| SF6 in HV switchgear | 1 | kg added or recovered | Service reports | GWP from one IPCC report | Electrical |
| Grid electricity | 2 | kWh per month, per meter | Electricity bills, sub-meters | CEA grid factor, version noted | Electrical |
| Purchased steam or heat | 2 | Tonnes of steam or GJ | Supplier invoices | Supplier value | Utilities |
| Purchased raw materials | 3 | Tonnes by material | Purchase records | Supplier or published database | Purchase |
| Inbound and outbound transport | 3 | Tonne-km or litres | Transporter records | Published database | Logistics |
A DG set's diesel is counted once, in Scope 1. Do not add the electricity it made to Scope 2.
Worked example: an induction foundry in Kolhapur
Worked example (illustrative)
Take a grey iron foundry in Kolhapur with two induction furnaces, a sand plant, two DG sets for backup and a few chillers for the furnace cooling water. Here is one month of Scope 1 and 2. Every number, including the factors, is illustrative. Use current published factors for your own plant.
The factors used: diesel 2.68 kg CO2 per litre, LPG 2.98 kg CO2 per kg, refrigerant R-410A with a GWP of 2,088, and a grid factor of 0.72 t CO2 per MWh.
| Source | Scope | Activity (one month) | Factor (illustrative) | Emissions |
|---|---|---|---|---|
| DG sets and forklifts: diesel | 1 | 12,000 litres | 2.68 kg CO2 per litre | 32.2 tCO2 |
| Ladle preheating: LPG | 1 | 8,000 kg | 2.98 kg CO2 per kg | 23.8 tCO2 |
| Chiller leak top-up: R-410A | 1 | 10 kg | GWP 2,088 | 20.9 tCO2e |
| Grid electricity | 2 | 900 MWh | 0.72 t CO2 per MWh | 648.0 tCO2 |
| Total Scope 1 and 2 | 724.9 tCO2e |
What the example shows (illustrative). In an induction foundry, electricity dwarfs everything else, so energy per tonne of good castings is the number to watch. Two smaller lines matter to maintenance. A 10 kg refrigerant top-up looks minor in a service report, yet here it equals almost two thirds of a month of DG and forklift diesel. And if a leak survey on the compressed air network saves 6 MWh a month, that is about 4.3 tCO2 a month off Scope 2, before you count the lower power bill.
Where maintenance data feeds the inventory
Most of the hard Scope 1 data in a plant is already in maintenance hands. It is just scattered.
The DG fuel log and run hours sit with the maintenance team. Refrigerant top-ups appear in chiller and AC service reports, often without the gas type or the quantity. SF6 handling is in the electrical contractor's report. Furnace and boiler fuel often comes through stores, but the burner tuning and efficiency checks that decide how much of it you use are maintenance jobs.
On the Scope 2 side, maintenance controls the biggest levers you can pull without new capital: compressed air leaks, motor and pump efficiency, worn furnace coils and refractory, and idle running. A preventive schedule that keeps these in shape lowers emissions as well as the bill.
So the simplest improvement is to make every relevant job record the quantity and the unit. A refrigerant work order that says "gas topped up" is useless for a GHG inventory. One that says "R-32, 2.4 kg added, leak found at flare nut, fixed" is evidence.
Common mistakes
- Counting DG power twice. The diesel is Scope 1. The units the DG made are not Scope 2.
- Mixing units. LPG bought in kg and booked in litres, or electricity in kWh against a factor per MWh. Write the unit in every row.
- Using an old grid factor. The CEA factor is revised. A factor copied from a three year old report gives the wrong answer and no auditor will accept it without a version.
- Forgetting refrigerants and SF6. They are small in kilograms and large in tCO2e because of their high GWP.
- Mixing GWP values from different IPCC reports. Pick one report for all gases and all years.
- Starting with Scope 3. Scope 3 is usually the largest share, but its data is the weakest. Get Scope 1 and 2 right and repeatable first, then add the Scope 3 categories that matter most.
- No evidence trail. A total with no invoice, meter reading or work order behind it will not survive a customer audit or an assurance review.
Sources
- GHG Protocol Corporate Accounting and Reporting Standard (opens in a new tab), GHG Protocol (WRI and WBCSD)
- GHG Protocol Scope 2 Guidance (opens in a new tab), GHG Protocol (WRI and WBCSD)
- Corporate Value Chain (Scope 3) Standard (opens in a new tab), GHG Protocol (WRI and WBCSD)
- 2006 IPCC Guidelines for National Greenhouse Gas Inventories (opens in a new tab), IPCC
- Central Electricity Authority (publisher of the CO2 Baseline Database for the Indian power sector) (opens in a new tab), Central Electricity Authority, Government of India
- Business responsibility and sustainability reporting by listed entities (circular, 10 May 2021) (opens in a new tab), SEBI
Frequently asked questions
What is the difference between Scope 1, 2 and 3 emissions?
Scope 1 is direct emissions from sources you own or control, such as fuel burnt on site and refrigerant leaks. Scope 2 is emissions from electricity, steam or heat you buy. Scope 3 is all other indirect emissions in your value chain, such as purchased materials and transport.
How do you calculate GHG emissions?
Multiply each activity, such as litres of diesel or kWh of electricity, by its emission factor. For gases other than CO2, multiply by the global warming potential to get CO2 equivalent. Add every source to get tonnes of CO2e.
Which grid emission factor should an Indian factory use?
For a location-based Scope 2 figure, use the latest grid emission factor in the CO2 Baseline Database published by the Central Electricity Authority, and record the version you used.
Is diesel used in a DG set Scope 1 or Scope 2?
Scope 1. You burn the fuel on your own site. The electricity the DG set produces is not counted again in Scope 2.
Do refrigerant leaks count as emissions?
Yes. Refrigerant that leaks from chillers, air conditioners and cold rooms is a Scope 1 emission. Use the quantity topped up as the activity data and the gas's global warming potential to convert it to CO2e.
Does a factory have to report Scope 3?
It depends on who is asking. Large customers and reporting schemes increasingly ask for it. Most plants start with Scope 1 and 2, then add the Scope 3 categories that are largest for them, such as purchased materials and transport.